Quality documents
Peptide COA library and reading guide
A certificate of analysis (COA) is the laboratory record for one specific lot of material. This page does two things: it lets you find the published COA for the lot you hold, and it explains, step by step, how to read what that document actually says. All products are supplied for laboratory research use only and are not for human or veterinary use.
COA library
| Compound | Fill | Lot | Purity (HPLC) | Test date | Download |
|---|---|---|---|---|---|
| BPC-157 | 10 mg | 07022026-004 | 99.74% | July 21, 2026 | Download PDF |
| BPC-157 | 20 mg | 20260813-2 | 99.7% | September 2, 2026 | Download PDF |
| BPC-157 + TB-500 blend | 20 mg | 20260812-7 | 99.7% | August 19, 2026 | Download PDF |
| TB-500 | 10 mg | 20260813-4 | 99.1% | September 15, 2026 | Download PDF |
| GHK-Cu | 100 mg | 260807-4 | 99.6% | August 14, 2026 | Download PDF |
| GLOW blend | 70 mg | 20260813-3 | 99.1% | September 3, 2026 | Download PDF |
| Ipamorelin | 10 mg | 20260710/8 | 99.1% | September 2, 2026 | Download PDF |
| Kisspeptin | 10 mg | 07022026-028 | 99.82% | July 23, 2026 | Download PDF |
| KPV | 10 mg | 260807-3 | 99.8% | August 20, 2026 | Download PDF |
| MOTS-c | 10 mg | 20260702-001 | 99.51% | August 7, 2026 | Download PDF |
| MOTS-c | 20 mg | 20260824-4 | 99.3% | September 15, 2026 | Download PDF |
| NAD+ | 500 mg | See COA PDF | 99.83% | August 5, 2026 | Download PDF |
| NAD+ | 1000 mg | 260807-5 | 99.3% | August 19, 2026 | Download PDF |
| Selank + Semax | 10 mg | 07022026-042 | 99.80% | See COA PDF | Download PDF |
| Semax | 10 mg | BTCH-PE-101-404 | 99.7% | September 4, 2026 | Download PDF |
| Tesamorelin | 10 mg | 20260706-006 | 99.36% | August 7, 2026 | Download PDF |
No published COA matches that lot. Send us your lot and order number and we'll send the certificate. Request a lot COA
What a certificate of analysis is
A COA is a test report tied to one production lot. It is not a general product sheet and it is not a promise about every vial ever made. When a lot is manufactured, a sample from that lot is analysed and the results are recorded against the lot number. If the lot number on your vial does not match the lot number on the certificate, the certificate is not describing your material.
A useful COA answers four questions: what was tested, which lot it came from, how it was tested, and who tested it and when. Anything missing from that list reduces what the document can tell you.
The fields on a COA, in order
- Compound name and fill size โ what the lot is labelled as, and the nominal amount per vial (for example, 10 mg).
- Lot (batch) number โ the key that links the paper to the physical vial.
- Test date โ when the analysis was run. Older dates are normal for stable lyophilised material, but the test date should come after the manufacture date.
- Laboratory โ the lab that ran the analysis.
- Purity by HPLC โ a percentage, ideally with the detection wavelength stated.
- Identity by MS โ the observed mass compared with the expected (theoretical) mass.
- Appearance โ usually "white to off-white lyophilised powder".
- Chromatogram and spectrum images โ the raw traces behind the numbers.
What HPLC shows
High-performance liquid chromatography (HPLC) separates the components of a sample as it passes through a column. A detector, usually UV at a stated wavelength such as 214 or 220 nm, records a peak for each component. The purity figure is the area of the main peak divided by the total area of all detected peaks โ "area percent".
What that means in practice:
- It is relative, not absolute. Area percent tells you how much of what the detector saw belongs to the main peak. It does not tell you the total peptide mass in the vial; water, counter-ions and salts do not appear as peaks. That separate figure is net peptide content (see HPLC area percent vs net peptide content).
- The wavelength matters. Different wavelengths can give slightly different numbers. A purity value with no wavelength is harder to compare.
- Look at the chromatogram. A clean report shows one dominant, sharp peak and small side peaks. A stated purity that does not match the picture is a red flag.
What MS shows
Mass spectrometry (MS) measures the mass of the molecules in the sample. For a peptide, the lab compares the observed mass with the theoretical mass calculated from the sequence. A close match confirms identity: that the main component is the molecule named on the label.
HPLC and MS answer different questions. HPLC says how clean the sample is; MS says what the main component is. A high HPLC purity with no MS identity tells you the sample is clean, but not that it is the right compound. You want both, on the same lot.
When reading the MS section, check that:
- the expected mass is stated, and the observed mass is close to it;
- multiply-charged ions, if shown, are consistent with the same molecule;
- the spectrum belongs to the same lot number as the HPLC result.
How to match your vial to its COA
- Read the lot number on the vial label (and on the box, if present). Note it exactly, including letters and dashes.
- Find that lot in the library above. Search by lot, or filter by compound and fill size.
- Open the PDF and compare the lot number, compound name and fill size with your label. All three should match.
- Check that the date and laboratory fields are present.
- If you cannot find your lot, contact us with the lot number and order number. Published Lab COA PDFs are listed in the COA library.
A COA for the same compound but a different lot is not evidence about your vial. That is the whole point of lot matching.
Common red flags on any supplier's COA
- No lot number, or a lot number that never changes across orders.
- A purity figure with no chromatogram, no wavelength and no lab name.
- Identity claimed without an MS result or expected mass.
- A test date before the stated manufacture date.
- Identical documents reused across different compounds or fill sizes.
- Images cropped so that the lab name or lot cannot be read.
For a broader checklist, see how to verify a peptide supplier.
What a COA does not tell you
A COA describes the composition of a tested sample. It does not describe suitability for any use outside the laboratory, and it is not a statement about biological activity or outcomes. Storage and handling after delivery also matter: lyophilised material is generally kept cold, dry and away from light, following the documented storage conditions.
Further reading
COA questions
What is a certificate of analysis (COA)?
A COA is the laboratory test report for one production lot. It records the lot number, test date, laboratory, HPLC purity and MS identity for a sample of that lot.
How do I find the COA for my vial?
Read the lot number on the vial label and search for it in the COA library on this page. If your lot is not listed, contact us with the lot and order number and we will send it.
What does HPLC purity mean?
It is the area of the main peak as a percentage of all peaks detected at the stated wavelength. It shows how clean the sample is, not the total peptide mass in the vial.
What does the MS result show?
Mass spectrometry compares the observed molecular mass with the expected mass for the sequence, confirming the identity of the main component.
Is a COA for a different lot valid for my vial?
No. A COA only describes the lot it was issued for. Always match the lot number on the vial to the lot number on the certificate.
Are these products for human use?
No. All products are supplied for laboratory research use only and are not for human or veterinary use.
Request a lot COA by email
COA by email
Enter the catalog code and the lot number printed on your vial. We reply by email about the lot-specific COA within one business day.
All BioLabs Research products are for laboratory research use only. Not for human or veterinary use, not for consumption, not for diagnostic or therapeutic use.